Program Overview
Arrive on the scene of an active gas leak emergency, where you must employ your investigation techniques and safety protocol correctly to preserve life and property quickly, accurately, and efficiently. Work alone or with an instructor to complete four common emergency scenarios.
To see a video of the module, click this link: ERS Walkthrough
Core Learning Objectives
-
Recognize emergent hazardous conditions using sense of sight, simulated smell, and hearing.
-
Identify and eliminate all ignition sources.
-
Know when to evacuate and how to ventilate occupied buildings.
-
Apply proper investigation techniques to monitor changing conditions and properly escalate any relevant changes.
-
Develop strong communication patterns during emergency situations
Tools
-
Laser Pointer — to interact with menus and objects in this experience, aim your laser pointer at the item you wish to interact with and pull the trigger on your controller to select it.
-
Soap Spray — to test for a leak, aim the spray and pull the controller trigger:
-
If bubbles appear, there is a leak
-
If there are no bubbles, the leak is coming from somewhere else
-
-
CGI Tool — to take gas readings on any interactive object where gas might be present, aim and pull the controller trigger. After pulling the trigger, floating percentages will appear.
-
Adjustable Wrench — to turn off gas meters, aim and pull the controller trigger.
-
Valve Key — to turn off gas flow at mainline valves:
-
Select the Valve with your laser pointer
-
Select Open Valve Box Lid
-
Open Wrist Menu > Toolbox
-
Select the Valve Key with your laser pointer to equip it
-
Physically place the valve key near valve box and it will snap into place
-
-
Traffic Cone — to block off the street and mark opened manhole covers, aim and pull the controller trigger to drop/place cones.
-
Rock Drill — to drill holes in the concrete or asphalt to check for gas, aim and pull the controller trigger. After pulling the trigger, floating percentages will appear.
-
Shovel — no functionality in ERS Module.
-
Plunger Bar — to create a bar hole, use the red circle to aim, then pull the controller trigger to drop the probe.
-
Red Cone — to mark off the Incident Command Center at the end of the road, place four cones in a square formation around the command center. To place cones, aim and pull the trigger on your controller.
-
Heath Sensor — additional gas detector.
-
Anemometer — to see the cardinal direction that the user is facing, wind speed, and wind direction, pull the controller trigger
How to Get 100%
The core scenarios for this module are as follows:
-
Centerline Gas Leak
-
Excavation Ignition
-
Excavation Blowing
-
Excavation Burning
Tip: To choose a specific scenario, use the left and right arrows in the lobby and the laser pointer to select a scenario.
Good to know
Use the Wrist Menu for additional help within the module:
-
Dispatch Menu — contact various personnel to communicate status
-
Map — quick reference guide showing gas lines in the neighborhood
-
Toolbox — access tools. see the Tools section to learn how to use tool
-
Work Order — references Work Order
After using the fire chief to evacuate the houses, wait until every NPC comes to a stop before reporting the evacuation to dispatch.
Centerline Leak
- Scan all 4 sides of the door and enter the house and scan the entry way.
- Don't hit the doorbell or you will lose a point.
- If the house has gas but also has a meter on the side and a small curb valve, do not interact with the meter. Only use the Valve Key on the small curb valve.
- Scan everything before reporting the centerline leak. Scanning the manholes is what allows the task to be completed.
- Report the gas in the Centerline Sewer to the Supervisor.
- After using the fire chief to evacuate the houses, wait until every NPC comes to a stop before reporting the evacuation to dispatch.
Blowing
- Request both fire department and gas crew every time regardless of whether the fire department is there or not.
Ignition
- Ignited gas should be reported to the Dispatch and the Supervisor.
- Fire Department present should only be reported to Dispatch.
- Request both fire department and gas crew every time regardless of whether the fire department is there or not.
Burning
- Request both fire department and gas crew every time regardless of whether the fire department is there or not.
Centerline Gas Leak Scenario
1. Read and close the Work Order (use the laser pointer to open/close menus).
2. Equip all PPE from the PPE selection van before doing anything else (see Wrist Menu > Map for location). Select each PPE icon with the laser pointer to equip.
3. Use the address from the Work Order and the Facility Map (Wrist Menu > Map) to find the Customer's home. Note: the Customer's address is randomized each play through.
4. At every house on the block, knock on the door:
o Physically touch the door with your virtual hands. Don't hit the doorbell or you will lose a point.
o Select “I need to check your doorway for gas concentrations.”
5. Scan all 4 sides of the door [Make sure to scan very thoroughly], then enter the house and scan the entry way, using the CGI Tool (Wrist Menu > Toolbox to equip).
6. If gas is >0% in a customer's doorway, evacuate the house:
o Select the Customer, then select “I need you to please evacuate your premises immediately.”
o Wait until the NPC comes to a stop and then report the evacuation to Dispatch.
▪ Report the evacuation for every house that has gas.
o Terminating the service to the house and reporting can be done here as well if wanted.
7. Test the surrounding area for leaks: scan all manholes, sewers, grates (storm drains), and valve boxes. Scan everything before reporting the centerline leak; scanning the manholes is what allows the task to be completed.
o Scan the manholes on the very ends of the street. They are not interactable but need to be scanned.
8. Report the gas in the centerline sewer:
o Wrist Menu > Communication > Communicate Status.
o Select Detected high gas levels in centerline sewer.
o Select Supervisor.
9. Ventilate every manhole and valve box that has gas:
o Select the manhole, choose Open Manhole, and surround it with traffic cones from the Toolbox.
o Select the valve box, choose Open valve box lid.
10. Return to the home with the leak and turn off service [Don’t do if done earlier]:
o If the house has a meter on the side and a small curb valve, do not interact with the meter. Only use the Valve Key on the small curb valve.
o If the house only has a meter, use the Adjustable Wrench on the meter.
11. Report the shutoff [Don’t do if done earlier]:
o Wrist Menu > Communication > Communicate Status > Terminated Gas Service Valve/Meter > Company Dispatch.
12. Test each customer's service using the CGI and Plunger Bar to find the leak source. Check the front of all homes (flower beds), the parkways and the service lines.
o Put multiple plunger bars in every area. Line the entire grassy area for each section.
▪ Tip: The user can enter Centerline Leak and immediately exit and go into the Review Room to identify where the scored areas are located.
▪ Tip: Once the leak is found, spamming the entire area in a circle is the best way to identify its highest level.
13. Find 0% in four directions (zero out) from the highest concentration.
14. Re-scan the manholes, valves, and storm drains.
o Scan the manhole on the very ends as well. They are not interactable but need to be scanned.
15. Re-check the leak spots for any changes. If the leak has spread, find the new highest concentration.
16. Wrist Menu > End Session.
Excavation Ignition Scenario
1. Read and close the Work Order (use the laser pointer to open/close menus).
2. Equip all PPE from the PPE selection van. Select each PPE icon with the laser pointer to equip.
3. If media is present, notify dispatch:
o Wrist Menu > Communication > Communicate Status > Media Present > Company Dispatch.
4. Evacuate the media: select the media crew with the laser pointer, then select “Request media crew relocate to Cherry and Main.”
5. Wait until the media crew comes to a stop.
6. Contact dispatch about the blowing gas:
o Wrist Menu > Communication > Communicate Status > Blowing Gas Present > Company Dispatch and Supervisor.
7. Request the fire department and gas crew every time, regardless of whether the fire department is there or not:
o Wrist Menu > Communication > Ask for Support > Request both Fire Department and Gas Crew.
8. Once the fire department is on site, report it to Dispatch only:
o Wrist Menu > Communication > Communicate Status > Fire Department on Site > Company Dispatch.
9. If the fire department has not coned off the road, request the traffic cones be placed by the Fire Chief.
10. Set up the Incident Command post for the fire chief using red cones from the Toolbox. Place four Red Cones around the Fire Chief.
11. Ask the fire chief to evacuate the houses: select the fire chief with the laser pointer, then select Request evacuation of all houses.
12. Wait until every NPC comes to a stop before continuing.
13. Report that the Incident Commander has been contacted:
o Wrist Menu > Communication > Communicate Status > Contacted Incident Command > One Call Center.
14. Report that the houses have been evacuated:
o Wrist Menu > Communication > Communicate Status > Evacuated Structure > Company Dispatch.
15. When ignition occurs:
o Any houses that have not been evacuated need to be evacuated. Wait until every NPC comes to a stop before reporting.
▪ Using the Fire Chief to Evacuate earlier means no NPCs will be left to evacuate at this point.
o Report the ignited gas: Wrist Menu > Communication > Communicate Status > Ignited Gas Present > Company Dispatch and Supervisor.
16. Select all ignition sources in the neighborhood and choose the correct option. Ignore the lawn lamps. Ignition sources can include:
o Vehicles. [Ignition Source Only]
o People smoking or mowing the lawn (additional action: evacuate). [Use the combined option]
o People near a blowing or burning gas line (additional action: evacuate). [Use the combined option]
o Lights and lantern posts (not lawn lights). [Ignition Source Only]
o The excavator. [Ignition Source Only]
o Air conditioners (on the side of the house). [Ignition Source Only]
17. After evacuating people from ignition sources, wait until every NPC comes to a stop.
18. Go to the mainline valve boxes and turn off the mainline using the Valve Key from the Toolbox. [Both Mainline Valves]
o Select the valve, then select Open valve box lid.
o Wrist Menu > Toolbox > Valve Key.
o Physically place the Valve Key near the valve box; it will snap into place.
19. Report the mainline shutoff to the Supervisor:
o Wrist Menu > Communication > Communicate Status > Terminated Main Line > Supervisor.
20. Wrist Menu > End Session.
Excavation Blowing Scenario
1. Read and close the Work Order (use the laser pointer to open/close menus).
2. Equip all PPE from the PPE selection van. Select each PPE icon with the laser pointer to equip.
3. Contact dispatch about the blowing gas:
o Wrist Menu > Communication > Communicate Status > Blowing Gas Present > Company Dispatch and Supervisor. Tip: press Next to see more communication options.
4. If media is present, notify dispatch:
o Wrist Menu > Communication > Communicate Status > Media Present > Company Dispatch.
5. Evacuate the media: select the media crew with the laser pointer, then select “Request media crew relocate to Cherry and Main.”
6. Wait until the media crew comes to a stop.
7. Request the fire department and gas crew every time, regardless of whether the fire department is there or not:
o Wrist Menu > Communication > Ask for Support > Request both Fire Department and Gas Crew.
8. Once the fire department is on site, report it:
o Wrist Menu > Communication > Communicate Status > Fire Department on Site > Company Dispatch.
9. If the fire department has not coned off the road, request the traffic cones be placed by the Fire Chief.
10. Set up the Incident Command post for the fire chief using red cones from the Toolbox. Place four Red Cones around the Fire Chief.
11. Ask the fire chief to evacuate the houses: select the fire chief with the laser pointer, then select Request evacuation of all houses.
12. Wait until every NPC comes to a stop before continuing.
13. Report that the Incident Commander has been contacted:
o Wrist Menu > Communication > Communicate Status > Contacted Incident Command > One Call Center.
14. Report that the houses have been evacuated:
o Wrist Menu > Communication > Communicate Status > Evacuated Structure > Company Dispatch.
15. Select all ignition sources in the neighborhood and choose the correct option. Ignore the lawn lamps. Ignition sources can include:
o Vehicles. [Ignition Source Only]
o People smoking or mowing the lawn (additional action: evacuate). [Use the combined option]
o People near a blowing or burning gas line (additional action: evacuate). [Use the combined option]
o Lights and lantern posts (not lawn lights). [Ignition Source Only]
o The excavator. [Ignition Source Only]
o Air conditioners (on the side of the house). [Ignition Source Only]
16. After evacuating people from ignition sources, wait until every NPC comes to a stop.
17. Go to the mainline valve boxes and turn off the mainline using the Valve Key from the Toolbox. [Both Mainline Valves]
o Select the valve, then select Open valve box lid.
o Wrist Menu > Toolbox > Valve Key.
o Physically place the Valve Key near the valve box; it will snap into place.
18. Report the mainline shutoff to the Supervisor:
o Wrist Menu > Communication > Communicate Status > Terminated Main Line > Supervisor.
19. Wrist Menu > End Session.
Excavation Burning Scenario
1. Read and close the Work Order (use the laser pointer to open/close menus).
2. Equip all PPE from the PPE selection van. Select each PPE icon with the laser pointer to equip.
3. If media is present, notify dispatch:
o Wrist Menu > Communication > Communicate Status > Media Present > Company Dispatch. Tip: press Next to see more communication options.
4. Evacuate the media: select the media crew with the laser pointer, then select “Request media crew relocate to Cherry and Main.”
5. Wait until the media crew comes to a stop.
6. Contact dispatch about the burning gas:
o Wrist Menu > Communication > Communicate Status > Burning Gas Present > Company Dispatch and Supervisor.
7. Request the fire department and gas crew every time, regardless of whether the fire department is there or not:
o Wrist Menu > Communication > Ask for Support > Request both Fire Department and Gas Crew.
8. Once the fire department is on site, report it:
o Wrist Menu > Communication > Communicate Status > Fire Department on Site > Company Dispatch.
9. If the fire department has not coned off the road, request the traffic cones be placed by the Fire Chief.
10. Set up an Incident Command post for the fire chief using red cones from the Toolbox. Place four Red Cones around the Fire Chief.
11. Ask the fire chief to evacuate the houses: select the fire chief with the laser pointer, then select Request evacuation of all houses.
12. Wait until every NPC comes to a stop before continuing.
13. Report that the houses have been evacuated:
o Wrist Menu > Communication > Communicate Status > Evacuated Structure > Company Dispatch.
14. Report that the Incident Commander has been contacted:
o Wrist Menu > Communication > Communicate Status > Contacted Incident Command > One Call Center.
15. Select all ignition sources in the neighborhood and choose the correct option. Ignore the lawn lamps. Ignition sources can include:
o Vehicles. [Ignition Source Only]
o People smoking or mowing the lawn (additional action: evacuate). [Use the combined option]
o People near a blowing or burning gas line (additional action: evacuate). [Use the combined option]
o Lights and lantern posts (not lawn lights). [Ignition Source Only]
o The excavator. [Ignition Source Only]
o Air conditioners (on the side of the house). [Ignition Source Only]
16. After evacuating people from ignition sources, wait until every NPC comes to a stop.
17. Go to the mainline valve boxes and turn off the mainline using the Valve Key from the Toolbox. [Both Mainline Valves]
o Select the valve, then select Open valve box lid.
o Wrist Menu > Toolbox > Valve Key.
o Physically place the Valve Key near the valve box; it will snap into place.
18. Report the mainline shutoff to the Supervisor:
o Wrist Menu > Communication > Communicate Status > Terminated Main Line > Supervisor.
19. Wrist Menu > End Session.